Latest technique construction Karl Fischer Titrimeter to determine moisture contents in liquids and powders by titration methods.
Model : GED – 61
Auto Titration Control + Auto Zero Burette + Adjustable Timer + Visual & Audible Alarm.
Digital display 10 LED in line, 1-50mg sample size only, K.F. dispensing resolution 0.05ml, run ADD end indication in auto mode, Solenoid valve for automatic regent flow control, 30 seconds end point time, Pressure filling auto Zero 10ml burette with 0.05ml resolution, variable speed magnetic stirrer with On/Off control, input supply 220-230VAC ± 10%.
Standard Accessories
Burette 10ml clear glass, Reservoir bottle 500ml, Titration cell 200ml, Dual platinum electrode, Teflon coated stirring paddle, Nozzle, Moisture trap with rubber tubing, Rubber bellow for pumping air, instruction manual.
‘GOKO’ DIGITAL FLAME PHOTO METER
Na and K at single aspiration, Dual channel display, Narrow band interface filters to determine concentration of Na K, Li & Ca solution in clinical and soil test labs.
Model : GED- 65
Standard Specifications
2-1/2 digit LED display, instrument supplied with Na & K narrow band glass filters, measuring range Na & K : 0 to 100ppm sensitivity 5ppm, Accuracy ± 2% up to 40ppm and 5% above 40ppm. Repeatability ± 2 count, Silicon photodiode detector, LPG gas flame system, input supply 220-230VAC ± 10%.
Standard Accessories
Air Compressor Unit, Chimney, Air tubing, dust cover, working / instruction manual.
Model : GED- 66 (With 4 Filters)
Standard Specifications
2-1/2 digit LED display, instrument supplied with Na, K, Ca, Li narrow band glass filters, measuring range Na & K : 0 to 100ppm sensitivity 5ppm, Accuracy ± 2% up to 40ppm and 5% above 40ppm. Ca : 20 to 100ppm. Li : 10 to 100ppm. Sensitivity 10ppm, Repeatability ± 2 count, Silicon photodiode detector, LPG gas flame system, input supply 220-230VAC ± 10%.
Standard Accessories
Air Compressor Unit, Chimney, Air tubing, dust cover, working / instruction manual.
‘GOKO’ DIGITAL MELTING POINT APPARATUS
Model : 70
Designed for accurate determination of melting point of various materials by uniformly heating with Silicon oil / other media in temp. bath assembly. The Temperature Bath assembly equipped with immersion heater, Pt100 temp. probe, built-in capillary stand to find out melting point.
Standard Specifications
Display : 3-1/2 digit Bright LED
Heating Temp. Range : 2ºC above room temperature to 350°C
Heating Rate : 0-100%
Stirrer Rate : 0-100%
Accuracy : 1%
Heating : Slow and Fast heating provision
Power : 220-230VAC± 10%
Standard Accessories
Capillary tubes (100Nos.), Teflon paddle, Cleaning tools, Temp. probe, working / instruction manual.
|
|